Mercurial > illumos > illumos-gate
view usr/src/cmd/fm/dicts/FMD.po @ 12979:ab9ae749152f
PSARC/2009/617 Software Events Notification Parameters CLI
PSARC/2009/618 snmp-notify: SNMP Notification Daemon for Software Events
PSARC/2009/619 smtp-notify: Email Notification Daemon for Software Events
PSARC/2010/225 fmd for non-global Solaris zones
PSARC/2010/226 Solaris Instance UUID
PSARC/2010/227 nvlist_nvflag(3NVPAIR)
PSARC/2010/228 libfmevent additions
PSARC/2010/257 sysevent_evc_setpropnvl and sysevent_evc_getpropnvl
PSARC/2010/265 FMRI and FMA Event Stabilty, 'ireport' category 1 event class, and the 'sw' FMRI scheme
PSARC/2010/278 FMA/SMF integration: instance state transitions
PSARC/2010/279 Modelling panics within FMA
PSARC/2010/290 logadm.conf upgrade
6392476 fmdump needs to pretty-print
6393375 userland ereport/ireport event generation interfaces
6445732 Add email notification agent for FMA and software events
6804168 RFE: Allow an efficient means to monitor SMF services status changes
6866661 scf_values_destroy(3SCF) will segfault if is passed NULL
6884709 Add snmp notification agent for FMA and software events
6884712 Add private interface to tap into libfmd_msg macro expansion capabilities
6897919 fmd to run in a non-global zone
6897937 fmd use of non-private doors is not safe
6900081 add a UUID to Solaris kernel image for use in crashdump identification
6914884 model panic events as a defect diagnosis in FMA
6944862 fmd_case_open_uuid, fmd_case_uuisresolved, fmd_nvl_create_defect
6944866 log legacy sysevents in fmd
6944867 enumerate svc scheme in topo
6944868 software-diagnosis and software-response fmd modules
6944870 model SMF maintenance state as a defect diagnosis in FMA
6944876 savecore runs in foreground for systems with zfs root and dedicated dump
6965796 Implement notification parameters for SMF state transitions and FMA events
6968287 SUN-FM-MIB.mib needs to be updated to reflect Oracle information
6972331 logadm.conf upgrade PSARC/2010/290
author | Gavin Maltby <gavin.maltby@oracle.com> |
---|---|
date | Fri, 30 Jul 2010 17:04:17 +1000 |
parents | c13e2db06244 |
children |
line wrap: on
line source
# # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License (the "License"). # You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # # DO NOT EDIT -- this file is generated by the Event Registry. # # # General-purpose messages # msgid "syslog-msgs-message-template" msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n" # # Fault-related messages # # # # code: FMD-8000-0W # keys: defect.sunos.fmd.nosub # msgid "FMD-8000-0W.type" msgstr "Defect" msgid "FMD-8000-0W.severity" msgstr "Minor" msgid "FMD-8000-0W.description" msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed. Refer to %s for more information." msgid "FMD-8000-0W.response" msgstr "Error reports from the component will be logged for examination by Sun." msgid "FMD-8000-0W.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "FMD-8000-0W.action" msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." # # code: FMD-8000-11 # keys: defect.sunos.fmd.nodiagcode # msgid "FMD-8000-11.type" msgstr "Defect" msgid "FMD-8000-11.severity" msgstr "Minor" msgid "FMD-8000-11.description" msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists. Refer to %s for more information." msgid "FMD-8000-11.response" msgstr "The diagnosis has been saved in the fault log for examination by Sun." msgid "FMD-8000-11.impact" msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." msgid "FMD-8000-11.action" msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result. Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly." # # code: FMD-8000-2K # keys: defect.sunos.fmd.module # msgid "FMD-8000-2K.type" msgstr "Defect" msgid "FMD-8000-2K.severity" msgstr "Minor" msgid "FMD-8000-2K.description" msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled. Refer to %s for more information." msgid "FMD-8000-2K.response" msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." msgid "FMD-8000-2K.impact" msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." msgid "FMD-8000-2K.action" msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm reset <module> to reset the module." # # code: FMD-8000-3F # keys: defect.sunos.fmd.config # msgid "FMD-8000-3F.type" msgstr "Defect" msgid "FMD-8000-3F.severity" msgstr "Minor" msgid "FMD-8000-3F.description" msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file. Refer to %s for more information." msgid "FMD-8000-3F.response" msgstr "The module has been disabled. Events destined for the module will be saved for manual diagnosis." msgid "FMD-8000-3F.impact" msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur." msgid "FMD-8000-3F.action" msgstr "Use fmdump -v -u <EVENT-ID> to locate the module. Use fmadm load <module> to load the module after repairing its configuration." # # code: FMD-8000-4M # keys: list.repaired # msgid "FMD-8000-4M.type" msgstr "Repair" msgid "FMD-8000-4M.severity" msgstr "Minor" msgid "FMD-8000-4M.description" msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." msgid "FMD-8000-4M.response" msgstr "Some system components offlined because of the original fault may have been brought back online." msgid "FMD-8000-4M.impact" msgstr "Performance degradation of the system due to the original fault may have been recovered." msgid "FMD-8000-4M.action" msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components." # # code: FMD-8000-58 # keys: list.updated # msgid "FMD-8000-58.type" msgstr "Update" msgid "FMD-8000-58.severity" msgstr "Minor" msgid "FMD-8000-58.description" msgstr "Some faults associated with an event id have been addressed.\n Refer to %s for more information." msgid "FMD-8000-58.response" msgstr "Some system components offlined because of the original fault may have been brought back online." msgid "FMD-8000-58.impact" msgstr "Performance degradation of the system due to the original fault may have been recovered." msgid "FMD-8000-58.action" msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired." # # code: FMD-8000-6U # keys: list.resolved # msgid "FMD-8000-6U.type" msgstr "Resolved" msgid "FMD-8000-6U.severity" msgstr "Minor" msgid "FMD-8000-6U.description" msgstr "All faults associated with an event id have been addressed.\n Refer to %s for more information." msgid "FMD-8000-6U.response" msgstr "All system components offlined because of the original fault have been brought back online." msgid "FMD-8000-6U.impact" msgstr "Performance degradation of the system due to the original fault has been recovered." msgid "FMD-8000-6U.action" msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."