view usr/src/cmd/fm/dicts/FMD.po @ 12979:ab9ae749152f

PSARC/2009/617 Software Events Notification Parameters CLI PSARC/2009/618 snmp-notify: SNMP Notification Daemon for Software Events PSARC/2009/619 smtp-notify: Email Notification Daemon for Software Events PSARC/2010/225 fmd for non-global Solaris zones PSARC/2010/226 Solaris Instance UUID PSARC/2010/227 nvlist_nvflag(3NVPAIR) PSARC/2010/228 libfmevent additions PSARC/2010/257 sysevent_evc_setpropnvl and sysevent_evc_getpropnvl PSARC/2010/265 FMRI and FMA Event Stabilty, 'ireport' category 1 event class, and the 'sw' FMRI scheme PSARC/2010/278 FMA/SMF integration: instance state transitions PSARC/2010/279 Modelling panics within FMA PSARC/2010/290 logadm.conf upgrade 6392476 fmdump needs to pretty-print 6393375 userland ereport/ireport event generation interfaces 6445732 Add email notification agent for FMA and software events 6804168 RFE: Allow an efficient means to monitor SMF services status changes 6866661 scf_values_destroy(3SCF) will segfault if is passed NULL 6884709 Add snmp notification agent for FMA and software events 6884712 Add private interface to tap into libfmd_msg macro expansion capabilities 6897919 fmd to run in a non-global zone 6897937 fmd use of non-private doors is not safe 6900081 add a UUID to Solaris kernel image for use in crashdump identification 6914884 model panic events as a defect diagnosis in FMA 6944862 fmd_case_open_uuid, fmd_case_uuisresolved, fmd_nvl_create_defect 6944866 log legacy sysevents in fmd 6944867 enumerate svc scheme in topo 6944868 software-diagnosis and software-response fmd modules 6944870 model SMF maintenance state as a defect diagnosis in FMA 6944876 savecore runs in foreground for systems with zfs root and dedicated dump 6965796 Implement notification parameters for SMF state transitions and FMA events 6968287 SUN-FM-MIB.mib needs to be updated to reflect Oracle information 6972331 logadm.conf upgrade PSARC/2010/290
author Gavin Maltby <gavin.maltby@oracle.com>
date Fri, 30 Jul 2010 17:04:17 +1000
parents c13e2db06244
children
line wrap: on
line source

#
# Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#

# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# General-purpose messages
#
msgid "syslog-msgs-message-template"
msgstr "SUNW-MSG-ID: %s, TYPE: %s, VER: 1, SEVERITY: %s\nEVENT-TIME: %s\nPLATFORM: %s, CSN: %s, HOSTNAME: %s\nSOURCE: %s, REV: %s\nEVENT-ID: %s\nDESC: %s\nAUTO-RESPONSE: %s\nIMPACT: %s\nREC-ACTION: %s\n"
#
# Fault-related messages
#
#
#
# code: FMD-8000-0W
# keys: defect.sunos.fmd.nosub
#
msgid "FMD-8000-0W.type"
msgstr "Defect"
msgid "FMD-8000-0W.severity"
msgstr "Minor"
msgid "FMD-8000-0W.description"
msgstr "The Solaris Fault Manager received an event from a component to which no automated diagnosis software is currently subscribed.  Refer to %s for more information."
msgid "FMD-8000-0W.response"
msgstr "Error reports from the component will be logged for examination by Sun."
msgid "FMD-8000-0W.impact"
msgstr "Automated diagnosis and response for these events will not occur."
msgid "FMD-8000-0W.action"
msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly.  Contact Sun for support."
#
# code: FMD-8000-11
# keys: defect.sunos.fmd.nodiagcode
#
msgid "FMD-8000-11.type"
msgstr "Defect"
msgid "FMD-8000-11.severity"
msgstr "Minor"
msgid "FMD-8000-11.description"
msgstr "A Solaris Fault Manager component generated a diagnosis for which no message summary exists.  Refer to %s for more information."
msgid "FMD-8000-11.response"
msgstr "The diagnosis has been saved in the fault log for examination by Sun."
msgid "FMD-8000-11.impact"
msgstr "The fault log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
msgid "FMD-8000-11.action"
msgstr "Use fmdump -v -u <EVENT-ID> to view the diagnosis result.  Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly."
#
# code: FMD-8000-2K
# keys: defect.sunos.fmd.module
#
msgid "FMD-8000-2K.type"
msgstr "Defect"
msgid "FMD-8000-2K.severity"
msgstr "Minor"
msgid "FMD-8000-2K.description"
msgstr "A Solaris Fault Manager component has experienced an error that required the module to be disabled.  Refer to %s for more information."
msgid "FMD-8000-2K.response"
msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
msgid "FMD-8000-2K.impact"
msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
msgid "FMD-8000-2K.action"
msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm reset <module> to reset the module."
#
# code: FMD-8000-3F
# keys: defect.sunos.fmd.config
#
msgid "FMD-8000-3F.type"
msgstr "Defect"
msgid "FMD-8000-3F.severity"
msgstr "Minor"
msgid "FMD-8000-3F.description"
msgstr "A Solaris Fault Manager component could not load due to an erroroneous configuration file.  Refer to %s for more information."
msgid "FMD-8000-3F.response"
msgstr "The module has been disabled.  Events destined for the module will be saved for manual diagnosis."
msgid "FMD-8000-3F.impact"
msgstr "Automated diagnosis and response for subsequent events associated with this module will not occur."
msgid "FMD-8000-3F.action"
msgstr "Use fmdump -v -u <EVENT-ID> to locate the module.  Use fmadm load <module> to load the module after repairing its configuration."
#
# code: FMD-8000-4M
# keys: list.repaired
#
msgid "FMD-8000-4M.type"
msgstr "Repair"
msgid "FMD-8000-4M.severity"
msgstr "Minor"
msgid "FMD-8000-4M.description"
msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
msgid "FMD-8000-4M.response"
msgstr "Some system components offlined because of the original fault may have been brought back online."
msgid "FMD-8000-4M.impact"
msgstr "Performance degradation of the system due to the original fault may have been recovered."
msgid "FMD-8000-4M.action"
msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."
#
# code: FMD-8000-58
# keys: list.updated
#
msgid "FMD-8000-58.type"
msgstr "Update"
msgid "FMD-8000-58.severity"
msgstr "Minor"
msgid "FMD-8000-58.description"
msgstr "Some faults associated with an event id have been addressed.\n  Refer to %s for more information."
msgid "FMD-8000-58.response"
msgstr "Some system components offlined because of the original fault may have been brought back online."
msgid "FMD-8000-58.impact"
msgstr "Performance degradation of the system due to the original fault may have been recovered."
msgid "FMD-8000-58.action"
msgstr "Use fmadm faulty to identify the repaired components, and any suspects that still need to be repaired."
#
# code: FMD-8000-6U
# keys: list.resolved
#
msgid "FMD-8000-6U.type"
msgstr "Resolved"
msgid "FMD-8000-6U.severity"
msgstr "Minor"
msgid "FMD-8000-6U.description"
msgstr "All faults associated with an event id have been addressed.\n  Refer to %s for more information."
msgid "FMD-8000-6U.response"
msgstr "All system components offlined because of the original fault have been brought back online."
msgid "FMD-8000-6U.impact"
msgstr "Performance degradation of the system due to the original fault has been recovered."
msgid "FMD-8000-6U.action"
msgstr "Use fmdump -v -u <EVENT-ID> to identify the repaired components."