view usr/src/cmd/fm/dicts/SCA500.po @ 0:c9caec207d52 b86

Initial porting based on b86
author Koji Uno <koji.uno@sun.com>
date Tue, 02 Jun 2009 18:56:50 +0900
parents
children 1a15d5aaf794
line wrap: on
line source

#
# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
# Use is subject to license terms.
#
# CDDL HEADER START
#
# The contents of this file are subject to the terms of the
# Common Development and Distribution License (the "License").
# You may not use this file except in compliance with the License.
#
# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
# or http://www.opensolaris.org/os/licensing.
# See the License for the specific language governing permissions
# and limitations under the License.
#
# When distributing Covered Code, include this CDDL HEADER in each
# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
# If applicable, add the following below this CDDL HEADER, with the
# fields enclosed by brackets "[]" replaced with your own identifying
# information: Portions Copyright [yyyy] [name of copyright owner]
#
# CDDL HEADER END
#
#ident	"@(#)SCA500.po	1.2	06/12/21 SMI"
#
# DO NOT EDIT -- this file is generated by the Event Registry.
#
#
# code: SCA500-8000-0D
# keys: fault.io.sca500.hw
#
msgid "SCA500-8000-0D.type"
msgstr "Fault"
msgid "SCA500-8000-0D.severity"
msgstr "Major"
msgid "SCA500-8000-0D.description"
msgstr "The Solaris Fault Manager has detected a hardware failure on the Sun Crypto Accelerator 500 card.  Refer to %s for more information."
msgid "SCA500-8000-0D.response"
msgstr "The module has been disabled and un-registered as a hardware provider to the Solaris Cryptographic Framework."
msgid "SCA500-8000-0D.impact"
msgstr "The card will no longer function as a cryptographic accelerator."
msgid "SCA500-8000-0D.action"
msgstr "Ensure that the board is securely installed on the system.\n\nUse the cryptoadm(1M) command\n\ncryptoadm list -p\n\n\nto check whether 'dca/x' (where x is a number) is listed under 'kernel hardware\nproviders'. If so, run diagnostics on the hardware provider using SUNVTS\nfollowing the procedures described in the Sun Crypto Accelerator 1000 Board\nUser's Guide.\n\nUse the fmdump(1M) command\n\nfmdump -vu event-id\n\n\nto view the results of diagnosis and the specific Field Replaceable\nUnit (FRU) identified for replacement.\n\nThe event-id can be found in the EVENT-ID field of the message.\nFor example:\n\n\nEVENT-ID: 39b30371-f009-c76c-90ee-b245784d2277\n"